Solar Energy Research Institute

1)       Hall Effect Measurement System

        (Brand: Ecopia)

        (Model: HMS-3000)

 

 

Items

Details

Description

An analytical technique that measures the electrical property such as charge carrier density, carrier mobility and resistivity of solid and thin film samples.

Magnetic Strength

0.57 T

Current Range

50 nA to 15 mA (Variable according to sample)

Type of Measurement

Carrier Concentration, Mobility and Resistivity

Type of Sample

Solid and Thin Film

Sample Geometry

Square (Preferably)

Sample size

(W x L x T)

Min: 1 cm x 1 cm x 1cm

Max: 3 cm x 3 cm x 3 cm

Operator

En. Mohamad Arif Mokhtar

(03-89217162/ arifseri@ukm.edu.my)

Charge

RM100/ sample (UKM’s staff and students) RM150/sample (External students and industry)

2)     
Light I-V Measurement (Power
Conversion Efficiency (PCE) Measurement)

(Brand: DR. OPTICAL) 

Specification
DR. OPTICAL
Description
An analytical technique that measures the power conversion
efficiency (PCE) of substrate and superstrate configured solar cell.
Voltage
Range
-5
V to +5 V
Current
Measurement
10
mA to 2.5 A
Type of
Measurement
Short
Circuit Current (Jsc), Open Circuit Voltage (Voc), Fill
Factor (FF) and Efficiency (%)
Type of
Sample
Substrate
and Superstrate Thin Film Solar Cells
Sample
Geometry
Variable
Sample size
(W x L x T)
Substrate: Variable
Superstrate: 30 mm x 30 mm x 1.1 mm
Operator
En. Mohamad Arif
Mokhtar
(03-89217162/
arifseri@ukm.edu.my)
 
Charge
RM120/ sample (UKM’s staff and students) RM150/sample (External students
and industry)
 

3)     EQE Measurement (IPCE Spectral Measurement)

      (Brand: K3100) 

Specification

K3100

Description

An analytical technique that measures incident-photon to current efficiency (IPCE) of substrate and superstrate type thin film solar cell

Wavelength Range

300 nm to 1200 nm

Type of Measurement

External Quantum Efficiency (EQE)

Type of Sample

Substrate and Superstrate Thin Film Solar Cells

Sample Geometry

Variable

Sample size

(W x L x T)

Substrate: Variable

Superstrate: 30 mm x 30 mm x 1.1 mm

Operator

En. Mohamad Arif Mokhtar

(03-89217162/ arifseri@ukm.edu.my)

 

Charge

RM150/ sample (UKM’s staff and students) RM200/sample (External students and industry)

 

4) Potentiostat / Galvanostat

 

        (Brand: Metrohm / Autolab)

Items

Details

Description

An analytical instrument includes a base potentiostat/galvanostat with a compliance voltage of  20 V and a maximum current of 400 mA. Equipped with frequency response analyzer (FRA) module and software for impedance measurement.

Potential Range    

+/- 10 V to 20 V

Compliance voltage

+/- 20 V to 40 V

Frequency Range

10 µHz – 32 MHz

Frequency range in combination with potentiostat

10 µHz – 5 MHz

Type of Measurement

Find circle, Element substraction, Kramers-Kronig.

Type of Sample

Electrolyte

Operator

En. Mohamad Arif Mokhtar

(03-89217162/ arifseri@ukm.edu.my)

Charge

RM200/ sample (UKM’s staff and students) RM350/sample (External students and industry)