Solar Energy Research Institute
Items | Details |
Description | An analytical technique that measures the electrical property such as charge carrier density, carrier mobility and resistivity of solid and thin film samples. |
Magnetic Strength | 0.57 T |
Current Range | 50 nA to 15 mA (Variable according to sample) |
Type of Measurement | Carrier Concentration, Mobility and Resistivity |
Type of Sample | Solid and Thin Film |
Sample Geometry | Square (Preferably) |
Sample size(W x L x T) | Min: 1 cm x 1 cm x 1cmMax: 3 cm x 3 cm x 3 cm |
Operator | En. Mohamad Arif Mokhtar(03-89217162/ arifseri@ukm.edu.my) |
Charge | RM100/ sample (UKM’s staff and students) RM150/sample (External students and industry) |
2)
Light I-V Measurement (Power
Conversion Efficiency (PCE) Measurement)
(Brand: DR. OPTICAL)
Specification | DR. OPTICAL |
Description | An analytical technique that measures the power conversion |
Voltage | -5 |
Current | 10 |
Type of | Short |
Type of | Substrate |
Sample | Variable |
Sample size(W x L x T) | Substrate: VariableSuperstrate: 30 mm x 30 mm x 1.1 mm |
Operator | En. Mohamad Arif |
Charge | RM120/ sample (UKM’s staff and students) RM150/sample (External students |
3) EQE Measurement (IPCE Spectral Measurement)
(Brand: K3100)
Specification | K3100 |
Description | An analytical technique that measures incident-photon to current efficiency (IPCE) of substrate and superstrate type thin film solar cell |
Wavelength Range | 300 nm to 1200 nm |
Type of Measurement | External Quantum Efficiency (EQE) |
Type of Sample | Substrate and Superstrate Thin Film Solar Cells |
Sample Geometry | Variable |
Sample size(W x L x T) | Substrate: VariableSuperstrate: 30 mm x 30 mm x 1.1 mm |
Operator | En. Mohamad Arif Mokhtar (03-89217162/ arifseri@ukm.edu.my)
|
Charge | RM150/ sample (UKM’s staff and students) RM200/sample (External students and industry)
|
4) Potentiostat / Galvanostat
(Brand: Metrohm / Autolab)
Items | Details |
Description | An analytical instrument includes a base potentiostat/galvanostat with a compliance voltage of 20 V and a maximum current of 400 mA. Equipped with frequency response analyzer (FRA) module and software for impedance measurement. |
Potential Range | +/- 10 V to 20 V |
Compliance voltage | +/- 20 V to 40 V |
Frequency Range | 10 µHz – 32 MHz |
Frequency range in combination with potentiostat | 10 µHz – 5 MHz |
Type of Measurement | Find circle, Element substraction, Kramers-Kronig. |
Type of Sample | Electrolyte |
Operator | En. Mohamad Arif Mokhtar (03-89217162/ arifseri@ukm.edu.my) |
Charge | RM200/ sample (UKM’s staff and students) RM350/sample (External students and industry) |