Preliminary characterisation on reaction between eriochrome cyanine R-aluminium (ECR-Al) or chrome azurol  S-aluminium (CAS-Al) complexes and fluoride ion was conducted by using UV-visible spectrophotometer. The  analytical results on the absorption spectra showed that both complexes were able to detect the presence of  fluoride ions. Other studies such as pH optimisation, calibration graph and reproducibility were also carried out  for both complexes. The reagent phases were prepared by adsorption of ECR-Al and CAS-Al complexes on XAD  2 co polymer which were later coupled to the distal end of bifurcated fibre. Stainless steel probe was immersed  in fluoride solution to produce chemical transduction system. The reflectance measurements of the immobilised  reagent, before and after reaction with analyte were conducted by using optical fibre spectrophotometer.

 

References

1.         Crosby,  N.T.,  Dennis,  A.L.  and  Stevens,  J.G.,  1968.  An  Evaluation  of  Some  Methods  for  the Determination of Fluoride in Portable Waters and Aqueous Solutions, Analyst, 93, 643-652.

2.         Rahimah, A.K. 1991. Ilmu Pergigian Pencegahan: Panduan Untuk Penuntut dan Pengamal Pergigian. Kuala Lumpur. Dewan Bahasa dan Pustaka.

3.         Musa, A. 1988. Penderia Kimia Gentian Optik. Buletin Kimia. 4(2): 52-60.

4.         Norrish, J.O.W. 1989. Current Status and Prospect for the Use of Optical Fibres in Chemical Analysis: A Review. Analyst 114:1359-1372.

5.         Wolfbeis, O.S. 1989. Novel Techniques and Materials for Fiber Optic Chemical Sensing Dalam ArdittyH.J.,  Darkin,  J.P.  dan  Kersten,  R.  (penyt),  Springer  Proceeding  in  Physics:  Optical  Fibre  Sensor, Heidelberg: Springer-Verlag 44: 416-424.

6.         Saari, L.A. 1987. trends in Fiber Optic Sensor Development. Trends in Analytical Chemistry. 4(7): 184-188.

7.         Mac Nulty, B.J., Hunter, G.J and Barrett, D.G. 1956. The Determination of Microgram Quantities of Fluoride, Analytica Chimica Acta 14: 368-380.

8.         Musa, A. 1996. Prob Bolehbuang Berasaskan Gentian Optik untuk Analisis Ion Al(III) di dalam Air. Sains Malaysiana. 25(3): 69-76.

9.         Narayanaswamy, R. , Russell, D.A. and Sevilla III, F. 1988. Optical Fibre Sensing of Fluoride Ions in a Flow Stream. 35(2): 83-88.

10.      David, A.R. and Narayanaswamy, R. 1989. Fibre Optic Fluorimetric Determination of Fluoride Ions. Analyst.114:381-385.

11.      Lange, N.A. 1967. Handbook of Chemistry, Edisi ke 10, USA: Mc Graw-Hill Book Company.

12.      Holzbecher, Z. 1976. Handbook of Organic Reagents in Inorganic Analysis. John Wiley & Son Inc. USA. 341-344.




Previous                    Content                    Next