The Malaysian Journal of Analytical Sciences Vol 12 No 2 (2008): 367 – 374

 

 

 

FORENSIC ANALYSIS  OF HIGH EXPLOSIVES RESIDUES IN

POST-BLAST WATER SAMPLES EMPLOYING SOLID PHASE EXTRACTION FOR ANALYTE PRO-CONCENTRATION

 

Umi K. Ahmad1*, Sumathy Rajendran1, Lee Woan Ling1 & Yew Chong Hooi2

 

1Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia

2PDRM Forensic Laboratory, 8 1/2 Mile Jalan Cheras, 43200 Cheras, Selangor, Malaysia

 

*Corresponding author: umi@kimia.fs.utm.my

 

Abstract

Nitroaromatic, nitramine and nitrate ester compounds are a major group of high order explosive or better known as military explosives. Octrahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 1,3,5-hexahydro -1,3,5-trinitrotriazine (RDX), 2,4,6-trinitro-toluene (TNT), pentaerythritol tetranitrate (PETN) and 2,4-dinitrotoluene (2,4-DNT) are secondary high explosives classified as most commonly used explosives components. There is an increasing demand for pre-concentration of these compounds in water samples as the sensitivity achieved by instrumental analytical methods for these high explosives residues are the main drawback in the application at trace levels for forensic analysis. Hence, a simple cartridge solid phase extraction (SPE) procedure was optimized as the off-line extraction and pre-concentration method to enhance the detection limit of high explosive residues using micellar electrokinetic chromatography (MEKC) and gas chromatography with electron-capture detection (GC-ECD) methods. The SPE cartridges utilized LiChrolut EN as the SPE adsorbent. By employing pre-concentration using SPE, the detection limits of the target analytes in water sample were lowered by more than 1000 times with good percentage recovery (> 87%) for MEKC method and lowered by 120 times with more than 2 % percentage recovery for GC-ECD methods. In order to test the feasibility of the developed method to real cases, post-blast water samples were analyzed. The post-blast water samples which were collected from Baling Bom training range, Ulu Kinta, Perak contained RDX and PETN in the range of 0.05 – 0.17 ppm and  0.0124 – 0.0390 ppm respectively.

 

Keywords: Solid phase extraction, high explosives, post-blast water samples, MEKC, GC-ECD, SPME.

 

References

1.       Ahmad, U.K., and Rajendran, S.  2007. E-proceeding in Regional Annual Fundamental Science Symposium (RAFSS). Skudai, Malaysia. 28-29 May 2007.

2.       Barshick, S.A, and Griest, W.H. 1998. Anal. Chem. 70. 3015-3020

3.       Calderara, S., Gardebas, D., and Martinez, F. 2003. Forensic Science International. 137. 6-12

4.       Groom, C.A., Beaubet, S., Halasz, A., Paquet, L., and Hawari, J. 2001.  J. Chromatogr. A. 909. 53-60

5.       Haderlein, S.B., Weissmahr, K.W., and Schwarzenbach, R.P. 1996. Environ. Sci. Technol. 30. 612-622

6.       Jackson, A.R.W. and Jackson, J.M.  2004. Forensic Science. UK: Prentice Hall

7.       Jenkins, T.F., Miyares, P.H., Myers, K.F., McCormick, E.F. and Strong, A.B. 1994. Anal. Chim. Acta. 289. 69-78

8.       Kleiböhmer, W., Cammann, K., Robert, J. and Mussenbrock, E. 1993. J. Chromatogr. 638. 349-356

9.       Lewin, U., Weerich, L., Efer, R. and Engewald, W. 1997.  Chromatographia. 45. 91-98

10.    Liska, I. 2000. Review Paper.  J. Chromatogr. A. 885. 3-16

11.    Lu, Q., Collins, G.E., Smith, M. and Wang, J.  2002. Anal.  Chim. Acta. 469. 253-260

12.    Northrop, D.M., Martire, D.E. and MacCrehan, W.A.  1991.  Anal. Chem. 63. 1038-1042

13.    Song, L., Xu, Z., Kang, J., and Cheng, J. 1997. J. Chromatogr. A. 780. 297-328

14.    Tagliaro, F. and Bortolotti, F.  2006. Electrophoresis. 27. 231-243

15.    Yinon, J., and Zitrin, S.  1993. “Modern Methods and Application in Analysis of Explosives”. England: John Wiley and Sons

 




Previous                    Content                    Next